front page » product » Open frame diesel generator set » Perkins » MP22(S)-1(404D-22G L) Specifications

loading

MP22(S)-1(404D-22G L) Specifications

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

General information                                    main strength                         support strength

Applicable standard

ISO 8528-5:2018

GB/T2820.(1~6)-2009

ce


environmental condition

Ambient temperature: +5°C~+40°C

Height: ≤1000m.

Note: If your condition is different from the above, please contact our sales.


factory examine

Full design and quality check

0%, 25%, 50%, 75%, 100%, 110% load test.

function test.

protection test


painting process

MPMC has the most advanced          Automatic spraying/powder coating  Production line, equipped with various sandblasting equipment      Ensure higher quality.

Canopy Painting: Henkel Pretreatment Process and World Famous Brands              Akzonobel powder.

Base frame coating: sandblasting process and Akzonobel powder          (Hempel Paint is optional).


Rated power (KVA)

20

22

Rated power (kW)

16

17.6

Frequency (Hz)

50

engine model

404d-22gl.

Engine speed (RPM)

1500

stage

3

PF.

0.8

Control System

digital

Rated voltage (V)

400/230

(According to customer requirements)

Tank capacity run time

≥8h@75% load


Fuel consumption

(l/h)

110% load

6.1


100% load

5.3


75% load

4.0


50% load

2.9

Picture 1picture 2

aspectweight

Picture 3.

Model

MP20-1

Opentype.

Length (l) mm

1610

Width (w) mm

650

Height (h) mm

1300

dry weight (kg)

550

Tank capacity (L)

90

The loading capacity (40'HC)

3

Note: Specifications and illustrations are subject to revision without notice

engine Specification


engine Model & manufacturer                                                                                                                                                                                                                                                      404D-22.GL (Perkins)

Emission Certification

Phase IIIA.

Number of cylinders

4

Cylinder device

queue

cycle

four lines

desire

turbocharged

drill x stroke

84x100mm

shift

2.216L

compressed rationing

23.3:1

main power/speed

18.7 kW / 1500 rpm

Backup Power/Speed

20.6 kW / 1500 rpm

accelerated governor

ems.

cooling system

forced water cooling cycle

frequency droop

≤5%

Total lubrication system capacity

10.6 L.

Coolant capacity (engine only)

3.6 L.

Fuel consumption

100% load

237 g/kwh @ 1500 rpm

beginner motor

DC 12V.

charging alternator

DC 12V.


heavy duty diesel engine

Anti-vibration mount

Replaceable fuel filter, oil filter and air filter

Cooling Heatsinks and Fans

Starting battery (with lead acid), including frame and cables

Flexible Fuel Connection Hose

Exhaust silencer and bellows

Operation Manual and Schematic Documentation


alternator Specification


alternator

number of stages

3

Power Factor (Cos Phi)

0.8

4

Insulation type

H Class.

winding tone

2/3

IP rating

IP23.

bearing

single bearing

Voltage Regulator

AVR

coupling

flexible disc


control control panel

Auto-start and auto-power-fail control modules

(alternator frequency and can speed sensing)



Picture 4.


key benefit

The ultimate size is the feature ratio.

Automatic transfer between power source (utility) and generator.

Hour counters provide accurate information on monitoring and maintenance deadlines.

User-friendly settings and button layout for ease of use.

Simultaneous monitoring of multiple parameters      Clear display The largest backlit icon display in its class.

The module can be controlled to suit various applications.

Compatible with various can engines, including Tier 4.

IP65 rating (with optional gasket) provides increased water ingress resistance.


key feature

Autostart and AMF mode in one module.

J1939-75 supports and can alarm ignore function.

Alternator frequency and speed sensing are available in a variant.

The largest backlit icon display in its class.

Heated display options.

A real-time clock provides accurate event logging.

Fully configurable via panel or PC using USB communication.

Extremely EFICE power saving mode.

3 phase generator induction.

3 Phase Power (Utility) Sensing

Compatible with 600 V pH, nominal system in pH.

Generator/load power monitoring (KW, KVA, KVAR, PF).

Cumulative power monitoring (kwh, kvah, kvarh).

Generator overload protection.

Generator/load current monitoring and protection.

Fuel and start output (configured when using CAN).

4 Configure the DC output.

3 Configure analog/digital input

4 Configure the digital inputs.

Configure staged load output.

3 engine maintenance alarm.

Engine speed protection.

Engine hours counter.

The engine warms up.

Engine runtime scheduler.

Engine idle control starts and stops.

Tier 4 engine gauge screen.

Battery voltage monitoring.

Start with a low battery voltage.

Configure the remote start input.

1 alternative configuration.

Comprehensive  warn,  electric  travel  or  shutdown  protection against fault conditions.

LCD alarm indication.

event log (50)

options

engine alternator Fuel System generate collection


water jacket preheater

oil preheater

oil painting pump

PMG stimulation

space heater

Winding temperature measurement

12/44 hours chassis

bundling fuel tank

external fuel tank

automatic fuel supply

switch between external jars      and bottom tank (three-way valve)

Controllers such as Deepsea, Comap, Smartgen, etc.

trailer

tool with machine

Picture 6.



Previous: 
Next: 

Quick Links

Product Categories

Contact us

Courtyard No. 2, Jiangmidian Street, Tongzhou District, Beijing

Room 2615, 26th Floor, Building 5

Tel: Tel./WhatsApp/WeChat
            86-13785672167
QQ: 932041610.
e-mail: bjxdgc@xindacreation.com
send us a message

©2021 Beijing Xinda Gongchuang Machinery Equipment Co., Ltd. All Rights Reserved

leadtechnologysupport Sitemap